VACUUM SENSOR 1 INSPECTION
2016 – MX-5 – Brakes
VACUUM SENSOR 1 INSPECTION
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
a. Select “DataLogger”.
b. Select “Modules”.
c. Select “EVP”.
3. Select the monitor item “VS1“ from the PID table.
4. Verify that the monitor value of monitor item “VS1“ is 40 kPa {300 mmHg, 12 inHg} or less.
-
If the monitor value is not 40 kPa {300 mmHg, 12 inHg} or less, replace the power brake unit. (See POWER BRAKE UNIT REMOVAL/INSTALLATION.)