HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]
HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]
SM2565352
id0140u0785600
Outline
Block Diagram
|
Operation
Output duty ratio |
Control condition |
---|---|
0%
|
• Engine stopped (excludes engine stop by i-stop control)
• Fuel cut injection control is in engine start zone
• Engine coolant temperature is -10 °C {14 °F}or less
• Other than battery voltage of 9—16 V
• Within a fixed period of time after engine start (varies according to engine coolant temperature)
|
0―100%
(Duty ratio determined by measuring the element temperature by the HO2S sensor heater element impedance)
|
• After engine warm-up (value fluctuates by battery condition, etc.)
|