HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]

HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]

SM2565352


id0140u0785600



Outline

• Based on the control of the HO2S heater, a stabilized oxygen concentration is detected even at low exhaust temperatures, and feedback control of fuel injection even at cold engine start is made possible for improved cold temperature exhaust emission performance.
• Both emission performance and sensor protection have been improved by duty control of the heater according to engine operation conditions (exhaust gas temperature)



Block Diagram

am3zzn00008281



Operation

• The PCM operates the HO2S heater based on the following control conditions.

Output duty ratio

Control condition

0%
• Engine stopped (excludes engine stop by i-stop control)
• Fuel cut injection control is in engine start zone
• Engine coolant temperature is -10 °C {14 °F}or less
• Other than battery voltage of 9—16 V
• Within a fixed period of time after engine start (varies according to engine coolant temperature)
0―100%
(Duty ratio determined by measuring the element temperature by the HO2S sensor heater element impedance)
• After engine warm-up (value fluctuates by battery condition, etc.)