REFRIGERANT PRESSURE SENSOR [MANUAL AIR CONDITIONER]
REFRIGERANT PRESSURE SENSOR [MANUAL AIR CONDITIONER]
SM2565469
id0740a2004600
Purpose/Function
Structure/Construction
|
Operation
1.Pressure is applied to the ceramic diaphragm of the detection area according to the refrigerant pressure in the cooler pipe.
|
2.The shape of the ceramic diaphragm changes by the applied pressure, and the amount of clearance between the electrodes changes.
3.The refrigerant pressure sensor detects the electrical load (capacitance) which changes according to the clearance amount, and converts it to a voltage value at the signal processing area. The voltage value characteristic increases if the refrigerant pressure increases, and decreases if the refrigerant pressure decreases.
|