Menu +
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

ACTUATOR [MANUAL AIR CONDITIONER]

ACTUATOR [MANUAL AIR CONDITIONER]

SM2565471


id0740a2006100



Air Mix Actuator


Purpose

• The air mix actuator moves the air mix door in the A/C unit to adjust the temperature of the air blown from the air vent.


Function

Door open/close function
• The door open/close function opens/closes the air mix door in the HOT or COLD positions.
Door position detection function
• The door position detection function fluctuates the potentiometer voltage value which is linked to the air mix actuator motor drive.


Structure/construction

• A potentiometer-type air mix actuator has been adopted.
• The air mix actuator is located on the passenger’s side of the A/C unit.
• The operation range of the air mix actuator is as indicated in the diagram.

am3zzn00008471


Operation

• For the air mix actuator operation, refer to the [MANUAL AIR CONDITIONING SYSTEM [MANUAL AIR CONDITIONER]]. (See MANUAL AIR CONDITIONER SYSTEM [MANUAL AIR CONDITIONER (US)].)



Airflow Mode Actuator


Purpose

• The airflow mode actuator moves the airflow mode door in the A/C unit to switch the air vent.


Function

Door open/close function
• The door open/close function opens/closes the airflow mode door in the VENT, BI-LEVEL, HEAT, DEF/HEAT, or DEFROSTER positions.
Door position detection function
• The door position detection function fluctuates the potentiometer voltage value which is linked to the airflow mode actuator motor drive.


Structure/construction

• A potentiometer-type airflow mode actuator has been adopted.
• The airflow mode actuator is located on the passenger’s side of the A/C unit.
• The operation range of the airflow mode actuator is as indicated in the diagram.

am3zzn00008472


Operation

• For the airflow mode actuator operation, refer to the [MANUAL AIR CONDITIONING SYSTEM [MANUAL AIR CONDITIONER]]. (See MANUAL AIR CONDITIONER SYSTEM [MANUAL AIR CONDITIONER (US)].)



Air Intake Actuator


Purpose

• The air intake actuator moves the air intake door in the blower unit to switch the air intake port.


Function

Door open/close function
• The door open/close function opens/closes the air intake door in the FRESH or RECIRCULATE positions.
Door position detection function
• The door position detection function fluctuates the potentiometer voltage value which is linked to the air intake actuator motor drive.


Structure/construction

• A potentiometer-type air intake actuator has been adopted.
• The air intake actuator is located on the blower unit.
• The operation range of the air intake actuator is as indicated in the diagram.

am3zzn00008473


Operation

• For the air intake actuator operation, refer to the [MANUAL AIR CONDITIONING SYSTEM [MANUAL AIR CONDITIONER]]. (See MANUAL AIR CONDITIONER SYSTEM [MANUAL AIR CONDITIONER (US)].)