NO.1 ANY OF THE FOLLOWING LIGHTS DO NOT ILLUMINATE WITH THE IGNITION ON: (ABS WARNING LIGHT, BRAKE SYSTEM WARNING LIGHT, TCS/DSC INDICATOR LIGHT AND/OR DSC OFF INDICATOR LIGHT) [DYNAMIC STABILITY CONTROL (DSC)]

NO.1 ANY OF THE FOLLOWING LIGHTS DO NOT ILLUMINATE WITH THE IGNITION ON: (ABS WARNING LIGHT, BRAKE SYSTEM WARNING LIGHT, TCS/DSC INDICATOR LIGHT AND/OR DSC OFF INDICATOR LIGHT) [DYNAMIC STABILITY CONTROL (DSC)]

SM2335152


id0403b2890600

Troubleshooting item

Any of the following lights do not illuminate with the ignition ON: (ABS warning light, brake system warning light, TCS/DSC indicator light and/or DSC OFF indicator light)

Possible cause
• DSC HU/CM does not operate.
• Communication error between DSC HU/CM and body control module (BCM)
• Communication error between body control module (BCM) and instrument cluster
• Instrument cluster malfunction
• DSC HU/CM internal malfunction

Diagnostic procedure

Step

Inspection

Results

Action

1
VERIFY WHERE MALFUNCTION IS IN WARNING LIGHTS AND INDICATOR LIGHTS’ COMMON POWER SUPPLY, OR IN OTHER WARNING LIGHTS AND INDICATOR LIGHTS
• Ignition is switched ON (engine off)
• Do other warning and indicator lights illuminate?
Yes
Go to Step 4.
No
Go to the next step.
*2
INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT
• Inspect the power supply circuit for an open circuit and short to ground. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning location, and perform the repair completion verification.
*3
INSPECT INSTRUMENT CLUSTER GROUND CIRCUIT FOR SHORT TO POWER SUPPLY AND OPEN CIRCUIT
• Inspect the ground circuit for an open circuit and short to power supply. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
Yes
Replace the instrument cluster, and perform the repair completion verification. (Open circuit in the instrument cluster)
No
Repair or replace the malfunctioning location, and perform the repair completion verification.
4
CONFIRM DSC HU/CM DTC
• Retrieve the DSC HU/CM DTC using the M-MDS. (See DTC INSPECTION.)
• Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
If communication error message is displayed on the M-MDS screen:
• Go to the next step.
If communication error message is not displayed:
• Go to Step 7.
*5
INSPECT DSC HU/CM POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT
• Inspect the power supply circuit for an open circuit and short to ground. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning location, and perform the repair completion verification.
*6
INSPECT DSC HU/CM GROUND CIRCUIT FOR SHORT TO POWER SUPPLY AND OPEN CIRCUIT
• Inspect the power supply circuit for an open circuit and short to power supply. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
Yes
Replace the DSC HU/CM, and perform the repair completion verification. (Open circuit in the DSC HU/CM)
No
Repair or replace the malfunctioning location, and perform the repair completion verification.
7
CONFIRM BODY CONTROL MODULE (BCM) DTC
• Retrieve the body control module (BCM) DTC using the M-MDS. (See DTC INSPECTION.)
• Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
Replace the instrument cluster, and perform the repair completion verification.
Repair completion verification
VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Install/connect the part removed/disconnected during the troubleshooting procedure.
• Has the malfunction symptom been eliminated?
Yes
Complete the symptom troubleshooting.
Explain to the customer what has been repaired.
No
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
• When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while doing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harness are connected correctly and undamaged.