SEAT WEIGHT SENSOR CALIBRATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]
SEAT WEIGHT SENSOR CALIBRATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]
SM2335912
id0810b4801700
Special Service Tool (SST)
MT04-S1-001-4
SEAT SENSOR CALIBRATION WEIGHT SET
|
-
Caution
-
• If any of the following work is performed, perform the seat weight sensor calibration using the M-MDS.
-
― Replacement with a new seat weight sensor― Replacement with a new seat weight sensor control module― Replacement with new passenger-side seat parts― Disassembly of the passenger-side seat
• If any of the following work is performed, perform the seat weight sensor inspection using the M-MDS. (See SEAT WEIGHT SENSOR INSPECTION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.].)-
― Removal of the passenger-side seat― Loosening and retightening of passenger’s seat fixing bolts― Or, the vehicle is involved in a collision
-
-
Note
-
• When seat weight sensor calibration is performed causing the SAS control module to detect the DTC, perform the following procedure.• The seat weight sensor calibration can be performed using the M-MDS. For details, follow the instructions displayed on the M-MDS.
1.Have four 10 kg (22 lb) weights from SST MT04-S1-001-4 ready to use.
2.Connect the M-MDS.
3.Perform the seat weight sensor calibration.