INSPECTION OF SST (DEPLOYMENT TOOL) [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]
INSPECTION OF SST (DEPLOYMENT TOOL) [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]
SM2335907
id0810b4801000
Special Service Tool (SST)
49 H066 002
Deployment tool
|
1.Before using the SST (49 H066 002), inspect its operation.
|
Inspection Procedure
1.Follow the steps below to inspect the SST (49 H066 002).
|
-
• If not as indicated in the table, replace the SST (49 H066 002) because it has a malfunction.
-
Warning
-
• Do not use a malfunctioning SST (49 H066 002), otherwise it could cause the air bag module or pre-tensioner seat belt to accidentally operate (deploy).
-
Caution
-
• Because the permissible voltage for the SST (49 H066 002) is 12 V, do not connect a 24 V power source because it will damage the SST. Always connect only a 12 V power source.
Step |
Inspection procedure |
Light condition |
|
---|---|---|---|
Green |
Red |
||
1
|
Connect the power supply red clip to the positive battery terminal, and the black clip to the negative battery terminal.
|
On
|
Off
|
2
|
Connect connectors A and B.
|
Off
|
On
|
3
|
Press the activation switch.
|
On
|
Off
|