SEAT WEIGHT SENSOR CALIBRATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]

SEAT WEIGHT SENSOR CALIBRATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]

SM2335912


id0810b4801700

Special Service Tool (SST)

MT04-S1-001-4
SEAT SENSOR CALIBRATION WEIGHT SET
Caution
• If any of the following work is performed, perform the seat weight sensor calibration using the M-MDS.
― Replacement with a new seat weight sensor
― Replacement with a new seat weight sensor control module
― Replacement with new passenger-side seat parts
― Disassembly of the passenger-side seat
• If any of the following work is performed, perform the seat weight sensor inspection using the M-MDS. (See SEAT WEIGHT SENSOR INSPECTION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.].)
― Removal of the passenger-side seat
― Loosening and retightening of passenger’s seat fixing bolts
― Or, the vehicle is involved in a collision
Note
• When seat weight sensor calibration is performed causing the SAS control module to detect the DTC, perform the following procedure.
• The seat weight sensor calibration can be performed using the M-MDS. For details, follow the instructions displayed on the M-MDS.

1.Have four 10 kg (22 lb) weights from SST MT04-S1-001-4 ready to use.

2.Connect the M-MDS.

3.Perform the seat weight sensor calibration.