CLOCK SPRING INSPECTION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]

CLOCK SPRING INSPECTION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.]

SM2335917


id0810b4802200

1.Disconnect the negative battery terminal and wait for 1 min or more. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)].)

2.Remove the clock spring. (See CLOCK SPRING REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.].)

3.Verify that the continuity is as indicated in the table.

• If not as indicated in the table, replace the clock spring. (See CLOCK SPRING REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM – US/CANADA SPEC.].)
am3zzw00036180
am3zzw00036181