REFRIGERANT PRESSURE CHECK [(US)]
REFRIGERANT PRESSURE CHECK [(US)]
SM2566249
id0710003002x1
1.Install the manifold gauge set. (See MANIFOLD GAUGE SET CONNECTION.)
2.Start the engine.
3.Prepare the vehicle as follows.
-
― Vehicle is not exposed to solar radiation― Engine speed: 1,500 rpm― A/C switch: ON― Air intake port: REC― Airflow mode: VENT― Airflow temperature: MAX COLD― Airflow volume: MAX HI― Hood: Open― All the doors and the trunk/liftgate: Close― All the windows: Close― Active air shutter (with active air shutter): Open
4.Wait for 8 min after the engine is started.
5.Record the pressure indicated on the manifold gauge and ambient temperature for 2 min.
6.Verify that there are high/low pressure value readings within the shaded areas of the figure.
Except Mexico Manufactured Vehicles
SKYACTIV-G 2.0, SKYACTIV-G 2.5 (HFC-134a)
|
Mexico Manufactured Vehicles
SKYACTIV-G 2.0, SKYACTIV-G 2.5 (HFC-134a)
|