INAPPROPRIATE OPERATION AND CONTROL RECORD 0x30 (TEMPERATURE RESTRICTION CONTROL) [PCM (SKYACTIV-G)]
INAPPROPRIATE OPERATION AND CONTROL RECORD 0x30 (TEMPERATURE RESTRICTION CONTROL) [PCM (SKYACTIV-G)]
SM2334394
id0102t4043000
-
Caution
-
The temperature restriction control is to prevent part damage. It is not a control which operates when a malfunction occurs. Therefore, do not replace the part.
Outline
Operation Conditions
Operation conditions
|
Determination conditions
|
• When any of the following condition is met:
|
Preconditions
|
• All of the following conditions are met:
|
Protection Control
Diagnosis Procedure and Explanation to Customer
STEP |
INSPECTION |
RESULTS |
ACTION |
---|---|---|---|
1
|
PURPOSE: VERIFY CONDITION WHEN INAPPROPRIATE OPERATION AND CONTROL CODE 0x30 (TEMPERATURE RESTRICTION CONTROL) IS OPERATED
• Did the condition meet the operation conditions?
|
Yes
|
Explain to the customer that the vehicle is normal and the temperature restriction control was performed to protect the vehicle.
|
No
|
Go to the next step.
|
||
2
|
PURPOSE: VERIFY IF THERE IS ANY MALFUNCTION
• Has any DTC or pending code been recorded?
|
Yes
|
Repair the malfunctioning location according to the applicable DTC troubleshooting.
|
No
|
The corresponding troubleshooting for the inappropriate operation and control code is completed.
|