Menu +
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

DIAGNOSTIC MONITORING TEST RESULTS [PCM (SKYACTIV-G)]

DIAGNOSTIC MONITORING TEST RESULTS [PCM (SKYACTIV-G)]

SM2334565


id0102t4801400

• The purpose of this test mode is to confirm the result of OBD-II monitor diagnostic test results. The result values stored when particular monitor is completed are displayed. If the monitor is not completed, initial value is displayed.

OBD Monitor ID

Test ID

Description

Related system

Scaling ID

Unit

01
80
A/F sensor lean-to-rich response time (calculated)
A/F sensor, HO2S
20
Ratio
01
81
A/F sensor rich-to-lean response time (calculated)
20
Ratio
01
82
A/F sensor lean-to-rich response time (calculated)
20
Ratio
01
83
A/F sensor rich-to-lean response time (calculated)
20
Ratio
02
03
Low HO2S voltage for switch time calculation (constant)
0A
Voltage
02
04
High HO2S voltage for switch time calculation (constant)
0A
Voltage
02
05
HO2S rich-to-lean response time (calculated)
10
Time
02
06
HO2S lean-to-rich response time (calculated)
10
Time
02
80
HO2S rich-to-lean response time out (calculated)
10
Time
21
82
Exponentially weighted moving average value of accumulative amount of fuel
Catalyst
36
g
35
80
Over-retarded (electric variable valve timing)
Variable valve timing
9C
deg.CA
35
81
Over-advanced (electric variable valve timing)
9C
deg.CA
35
82
Over-retarded (hydraulic variable valve timing)
9C
deg.CA
35
83
Over-advanced (hydraulic variable valve timing)
9C
deg.CA
35
84
Intake (A) camshaft position timing retard response time
10
Time
35
85
Intake (A) camshaft position timing advance response time
10
Time
3A
80
Phase 0 end pressure result and test limits
EVAP system
FE
Pa
3A
81
Phase 4 vapor generation minimum change in pressure and test limits
FE
Pa
3A
82
Phase 0 end pressure result and test limits
FE
Pa
3B
80
Phase 2 0.040” cruise leak check vacuum bleed-up and test limits
FE
Pa
3C
81
EONV positive pressure test result and limits
FE
Pa
3C
82
EONV negative pressure (vacuum) test result and limits
FE
Pa
3C
83
Normalized average of four EONV tests results and limits
03
Raw Value
3D
80
Blocked EVAP system line-screening test
A9
Pa/s
3D
81
Blocked EVAP system line-fault confirmation test
FE
Pa
41
80
A/F sensor heater test result and limits
A/F sensor, HO2S
14
ohm
42
80
HO2S heater test result and limits
14
ohm
A2
0B
Cylinder No.1 average misfire counts for last 10 Drive Cycle
Misfire
24
Counts
A2
0C
Cylinder No.1 misfire counts for last/current Drive Cycle
24
Counts
A3
0B
Cylinder No.2 average misfire counts for last 10 Drive Cycle
24
Counts
A3
0C
Cylinder No.2 misfire counts for last/current Drive Cycle
24
Counts
A4
0B
Cylinder No.3 average misfire counts for last 10 Drive Cycle
24
Counts
A4
0C
Cylinder No.3 misfire counts for last/current Drive Cycle
24
Counts
A5
0B
Cylinder No.4 average misfire counts for last 10 Drive Cycle
24
Counts
A5
0C
Cylinder No.4 misfire counts for last/current Drive Cycle
24
Counts