DSC OFF SWITCH INSPECTION
DSC OFF SWITCH INSPECTION
SM2335204
id041500802000
-
Note
-
• The DSC OFF switch is integrated with the cluster switch No.1.• For the DSC OFF switch removal/installation, refer to CLUSTER SWITCH REMOVAL/INSTALLATION. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)
1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)].)
2.Disconnect the cluster switch No.1 connector. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)
3.Attach the tester lead to the cluster switch No.1 wiring harness-side connector and inspect voltage or continuity according to the Terminal Voltage Table (Reference) on the table.
-
• If not as specified, repair or replace the related wiring harness.• If as specified, replace the cluster switch No.1. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)
Terminal Voltage Table (Reference)
|
—: Not applicable
Terminal |
Connected to |
Test item |
Test condition |
Specification |
Inspection item(s) |
---|---|---|---|---|---|
A
|
Instrument cluster
|
Continuity
|
Cluster switch No.1 terminal A—Instrument cluster B
|
Continuity
|
• Wiring harness between cluster switch No.1 terminal A and Instrument cluster terminal B
|
B
|
IG1 relay No.2
|
Voltage
|
Ignition is switched ON
|
B+
|
• Wiring harness between cluster switch No.1 terminal B and IG1 relay No.2 terminal C
|
Except above
|
1 V or less
|
||||
C
|
Instrument cluster
|
Continuity
|
Cluster switch No.1 terminal C—Instrument cluster AI
|
Continuity
|
• Wiring harness between cluster switch No.1 terminal C and Instrument cluster terminal AI
|
D
|
Ground point
|
Continuity
|
Under any condition
|
Continuity
|
• Wiring harness between cluster switch No.1 terminal D and ground point
|