Menu +
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [FULL-AUTO AIR CONDITIONER]

NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [FULL-AUTO AIR CONDITIONER]

SM2335676


id0703c1700600

Troubleshooting item

No temperature control with climate control unit

Description
• Temperature does not change when operating temperature control dial
Possible cause
• Dash-electrical supply unit detects DTC
― Detects DTC and activates fail-safe
• Air mix link malfunction
― Lack of grease
― Bad installation
• Air mix actuator malfunction
• Air mix door malfunction
― Bad installation
― Damage

Diagnostic Procedure

Step

Inspection

Action

1
INSPECT COOLANT TEMPERATURE
• Is the coolant sufficiently warmed up?
Yes
Go to the next step.
No
Warm up the engine, then perform the repair completion verification.
2
PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION
• Perform the dash-electrical supply unit DTC inspection using the M-MDS. (See DTC INSPECTION.)
• Are any DTCs displayed?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
3
INSPECT AIR MIX LINK PART
• Inspect the air mix actuator and air mix link.
― Is grease on link?
― Are links securely and properly installed?
― Are links free of obstructions and hindrances?
• Are the above items normal?
Yes
Go to the next step.
No
Apply grease or securely install to the correct positions.
If there is a malfunction in the air mix link, replace the air mix link.
Then perform the repair completion verification.
4
INSPECT AIR MIX ACTUATOR
• Inspect the air mix actuator. (See AIR MIX ACTUATOR INSPECTION [FULL-AUTO AIR CONDITIONER].)
• Is it normal?
Yes
Inspect the air mix door for the following items.
• Verify if there is no abnormal noise, cracks, or damage.
• Are doors securely and properly installed?
If there is foreign matter, remove it or securely install the air mix door to the correct position.
If the air mix door is cracked or damaged, replace the air mix door.
Then perform the repair completion verification.
No
Replace the air mix actuator, then perform the repair completion verification.
Repair completion verification
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Does the temperature change when the temperature control dial is operated?
Yes
Troubleshooting completed.
Explain repairs to customer.
No
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.