ALL SWITCH/DIAL OPERATION DOES NOT RESPOND [MANUAL AIR CONDITIONER]
ALL SWITCH/DIAL OPERATION DOES NOT RESPOND [MANUAL AIR CONDITIONER]
SM2335684
id0703c2005400
Troubleshooting item |
All switch/dial operation does not respond |
|
---|---|---|
Description
|
• All switch/dial operation of climate control unit does not respond
• Indicator light of climate control unit does not turn on
|
|
Possible cause
|
• Open circuit in climate control unit power supply circuit
• Short to ground in climate control unit power supply circuit
• Open circuit in climate control unit ground circuit
• Open circuit in dash-electrical supply unit power supply circuit
• Short to ground in dash-electrical supply unit power supply circuit
• Open circuit in dash-electrical supply unit ground circuit
• Ground point floating, bad contact
• Climate control unit malfunction
|
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1 *
|
INSPECT CLIMATE CONTROL UNIT POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT
• Inspect the power supply circuit for an open circuit and short to ground. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
2 *
|
INSPECT CLIMATE CONTROL UNIT GROUND CIRCUIT FOR OPEN CIRCUIT
• Inspect the ground circuit for an open circuit. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
3 *
|
INSPECT DASH-ELECTRICAL SUPPLY UNIT POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT
• Inspect the power supply circuit for an open circuit and short to ground. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
4 *
|
INSPECT DASH-ELECTRICAL SUPPLY UNIT GROUND CIRCUIT FOR OPEN CIRCUIT
• Inspect the ground circuit for an open circuit. (See CIRCUIT INSPECTION.)
• Is the circuit normal?
|
Yes
|
Replace the climate control unit, then go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
Repair completion verification
|
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Do the related parts operate according to the switch/dial operation of the climate control unit?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
|