AIR INTAKE MODE DOES NOT CHANGE [MANUAL AIR CONDITIONER]

AIR INTAKE MODE DOES NOT CHANGE [MANUAL AIR CONDITIONER]

SM2335687


id0703c2700500

Troubleshooting item

Air intake mode does not change

Description
• Air intake mode does not change when switching REC/FRESH mode
• No change in wind noise when airflow volume is set to 3 or more even if REC/FRESH switch is operated
Possible cause
• Dash-electrical supply unit detects DTC
― Detects DTC and activates fail-safe
• Air intake link malfunction
― Lack of grease
― Bad installation
• Air intake actuator malfunction
• Air intake door malfunction
― Bad installation
― Damage
• When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, inspect to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION
• Perform the dash-electrical supply unit DTC inspection using the M-MDS. (See DTC INSPECTION.)
• Are any DTCs displayed?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
INSPECT AIR INTAKE LINK
• Inspect air intake links. (See BLOWER UNIT DISASSEMBLY/ASSEMBLY [(US)].)
― Is grease on link?
― Are links securely and properly installed?
― Are links free of obstructions and hindrances?
• Are the above items normal?
Yes
Go to the next step.
No
Apply grease to links.
If any links are damaged, replace malfunctioning part.
Then perform the repair completion verification.
3
INSPECT AIR INTAKE ACTUATOR
• Inspect the air intake actuator. (See AIR INTAKE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER].)
• Is it normal?
Yes
Inspect the air intake doors, then perform the repair completion verification.
• If any doors are cracked or damaged, replace them.
• If any doors are not installed securely and properly. Install them in proper positions.
• If there are any obstructions, remove them.
No
Replace the air intake actuator, then perform the repair completion verification.
Repair completion verification
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Does the air intake mode change smoothly?
Yes
Troubleshooting completed.
Explain repairs to customer.
No
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.