WINDSHIELD FOGGED [MANUAL AIR CONDITIONER]

WINDSHIELD FOGGED [MANUAL AIR CONDITIONER]

SM2335689


id0703c2700700

Troubleshooting item

Windshield fogged

Description
• A/C compressor does not operate while airflow mode is in DEFROSTER or DEF/HEAT modes
• Air intake mode does not change to FRESH while airflow mode is in DEFROSTER or DEF/HEAT modes
Possible cause
• A/C compressor malfunction
• Dash-electrical supply unit detects DTC
― Detects DTC and activates fail-safe
• Air intake link malfunction
― Lack of grease
― Bad installation
• Air intake actuator malfunction
• Air intake door malfunction
― Bad installation
― Damage

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY THAT THERE IS COOL AIRFLOW
• Switch the A/C switch ON.
• Set the airflow volume control dial to 1 or more.
• Is there cool airflow from the vent?
Yes
Go to the next step.
No
Go to the following malfunction symptom item.
2
PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION
• Perform the dash-electrical supply unit DTC inspection using the M-MDS. (See DTC INSPECTION.)
• Are any DTCs displayed?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
3
INSPECT AIR INTAKE LINK PART
• Inspect the air intake actuator, air intake link for the following items.
― Is grease on link?
― Are links securely and properly installed?
― Are links free of obstructions and hindrances?
• Are the above items normal?
Yes
Inspect the air intake door for the following items.
• Verify if there is no abnormal noise, cracks, or damage.
• Are doors securely and properly installed?
If there is foreign matter, remove it or securely install the air intake door to the correct position.
If the air intake door is cracked or damaged, replace the air intake door.
Then perform the repair completion verification.
No
Apply grease or securely install to the correct positions.
If there is a malfunction in the air intake link, replace the air intake link.
Then perform the repair completion verification.
4
INSPECT AIR INTAKE ACTUATOR
• Inspect the air intake actuator. (See AIR INTAKE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER].)
• Is it normal?
Yes
Inspect the air intake door for the following items.
• Verify if there is no abnormal noise, cracks, or damage.
• Are doors securely and properly installed?
If there is foreign matter, remove it or securely install the air intake door to the correct position.
If the air intake door is cracked or damaged, replace the air intake door.
Then perform the repair completion verification.
No
Replace the air intake actuator, then perform the repair completion verification.
Repair completion verification
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Does the malfunction symptom recur?
Yes
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
No
Troubleshooting completed.
Explain repairs to customer.