DRIVER-SIDE DOOR GLASS CAN BE OPERATED MANUALLY BUT CANNOT BE OPERATED AUTOMATICALLY [POWER WINDOW SYSTEM]
DRIVER-SIDE DOOR GLASS CAN BE OPERATED MANUALLY BUT CANNOT BE OPERATED AUTOMATICALLY [POWER WINDOW SYSTEM]
SM2336277
id0903a0069800
Outline
Description
|
• Driver-side door glass can be operated manually but cannot be operated automatically.
|
Possible cause
|
• Power window main switch continuously operated
• Power window main switch malfunction
• Door-electrical supply unit (driver’s side) malfunction
|
Diagnostic Procedure
Step |
Inspection |
Results |
Action |
---|---|---|---|
1
|
VERIFY ALL SYSTEM DTCs
• Perform the DTC inspection. (See DTC INSPECTION.)
• Are any DTCs displayed?
|
Yes
|
Repair the malfunctioning location according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
INSPECT POWER WINDOW MAIN SWITCH FOR MALFUNCTION
• Inspect the applicable part. (See POWER WINDOW MAIN SWITCH INSPECTION [(US)].)
• Is the part normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
3
|
PERFORM POWER WINDOW SYSTEM INITIAL SETTING
• Perform the power window system initial setting. (See POWER WINDOW SYSTEM INITIALIZATION PROCEDURE.)
|
–
|
Go to the next step.
|
Repair completion verification
|
VERIFY THAT VEHICLE IS REPAIRED
• Install/connect the part removed/disconnected during the troubleshooting procedure.
• Has the malfunction symptom been eliminated?
|
Yes
|
Complete the symptom troubleshooting. (Explain contents of repair to customer)
|
No
|
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
• If the malfunction is not resolved, replace the door-electrical supply unit (driver’s side). (See DOOR-ELECTRICAL SUPPLY UNIT REMOVAL/INSTALLATION.)
|