FUEL-FILLER LID LOCK ACTUATOR INSPECTION

FUEL-FILLER LID LOCK ACTUATOR INSPECTION

SM2336425


id091400009600

1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)].)

2.Disconnect the fuel-filler lid lock actuator connector. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION [(US)].)

3.Apply battery positive voltage and connect the ground to the fuel-filler lid lock actuator terminals as indicated in the table below and verify the operation condition.

am3zzw00029247

B+ terminal

Ground terminal

Operation

A
B
Unlock
B
A
Lock
• If not as indicated in the table, replace the fuel-filler lid lock actuator. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION [(US)].)