FUEL-FILLER LID LOCK ACTUATOR INSPECTION
FUEL-FILLER LID LOCK ACTUATOR INSPECTION
SM2336425
id091400009600
1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)].)
2.Disconnect the fuel-filler lid lock actuator connector. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION [(US)].)
3.Apply battery positive voltage and connect the ground to the fuel-filler lid lock actuator terminals as indicated in the table below and verify the operation condition.
|
B+ terminal |
Ground terminal |
Operation |
---|---|---|
A
|
B
|
Unlock
|
B
|
A
|
Lock
|
-
• If not as indicated in the table, replace the fuel-filler lid lock actuator. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION [(US)].)