ELECTRIC VARIABLE VALVE TIMING ACTUATOR INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]

ELECTRIC VARIABLE VALVE TIMING ACTUATOR INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]

SM2565598


id0110u0555500

Warning
• A hot engine can cause severe burns. Turn off the engine and wait until it is cool before servicing.
Caution
• Do not disassemble the electric variable valve timing actuator because it is a precision unit.

1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)].)

2.Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))].)

3.Remove the electric variable valve timing motor/driver. (See ELECTRIC VARIABLE VALVE TIMING MOTOR/DRIVER REMOVAL/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))].)

4.Rotate the eccentric shaft of the electric variable valve timing actuator by hand and verify that it rotates smoothly.

am3uuw00009039
Note
• Hook a finger onto the joint groove of the eccentric shaft to rotate the shaft easily.
• The eccentric shaft stops rotating at the maximum retard position when it is rotated counterclockwise as viewed from the front, and at the maximum advance position when rotated clockwise.
• The eccentric shaft rotates 15.8 turns from the maximum retard position to the maximum advance position.

5.Install in the reverse order of removal.