FUEL-FILLER CAP INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]

FUEL-FILLER CAP INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]

SM2565772


id0116u0801300



Leakage Inspection

1.Perform the following tester (evaporative emission system tester (134-01049A)) self-test:

Note
• If the tester does not work correctly during self-test, refer to the tester operators manual for more detailed procedures.
(1)Verify that the gas cylinder valve is closed and the control valve located on the tester is in the TEST position. All tester displays should be off at this time.
(2)Connect the long hose (part of tester) to the tester.
ac5uuw00002689
(3)Connect the manifold assembly (part of tester) to the long hose as shown.
(4)Open the gas cylinder valve and verify the gas cylinder regulator left gauge reads 69—82 kPa {0.71—0.83 kgf/cm2, 10—12 psi} (preset at factory).
• If not, refer to the tester operators manual to contact tester manufacturer.
(5)Press the ON/OFF switch to turn on the SST and make sure the left display reads 0.0.
(6)Turn the control valve on the tester to the FILL position.
(7)Verify the left display reading is within 13.9 to 14.0 in of water.
• If not, adjust the pressure using the regulator knob located on the right side of the tester.
(8)Turn the control valve to TEST position and press the START switch.
(9)After the 2-min countdown (left display) is completed, the right display shows the total pressure loss for that period. A 0.5 in of water loss is acceptable on the self-test.
• If the loss is more than tester0.5 in of water, do one or more self-test. If the failed test repeats, check for leak using the ultrasonic leak detector (part of tester).

2.Press the RESET switch to set the left display reading to 0.0.

3.Connect the fuel cap receiver assembly (part of tester) to the manifold assembly and fuel-filler cap from the vehicle.

• If the fuel-filler cap is not a genuine part, replace it.
ac5uuw00002690

4.Turn the control valve to the FILL position.

5.Wait (maximum 20 s) until the left display reads 13.9 to 14.0 in of water.

• If the reading is slightly below the specification, adjust it using the regulator knob.
• If the reading is far below, the fuel-filler cap has a leak. Replace it.

6.Turn the control valve to the TEST position and press the START switch.

7.After the 2-min countdown (left display) is completed, check the test result (the failed/passed light on the tester).

• If the green light turns on, the fuel-filler cap is normal.
• If the red light turns on, the fuel-filler cap has a leak. Replace it.

8.Close the gas cylinder valve.

9.Turn the control valve to the FILL position.

10.Press the ON/OFF switch to turn off the tester.