CANISTER VENT (CV) SOLENOID VALVE INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]
CANISTER VENT (CV) SOLENOID VALVE INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]
SM2565783
id0116u0819200
U.S.A. And CANADA
Airflow inspection
1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)].)
2.Remove the CV solenoid valve. (See CANISTER VENT (CV) SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))].)
3.Inspect airflow between the ports under the following conditions.
|
Measured condition |
Continuity between ports A—B |
---|---|
When voltage is not applied between terminals A and B
|
Airflow detected
|
When voltage is applied between terminals A and B
|
No airflow
|
-
• If not as specified, replace the CV solenoid valve. (See CANISTER VENT (CV) SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))].)• Should assume the voltage 12 V (D.C.).• Terminals A and B is nonpolar.