PID/DATA MONITOR TABLE [ELECTRICAL SUPPLY UNIT (ESU) (US)]

PID/DATA MONITOR TABLE [ELECTRICAL SUPPLY UNIT (ESU) (US)]

SM2566313


id0902ff1205fg

PID

Unit/Operation

Data contents

Module control terminal

AUTO_HOLD_IND
Off/On
• Off: AUTOHOLD stand-by indicator light turns off.
• On: AUTOHOLD stand-by indicator light turns on.
1S
AUTO_HOLD_SW
Off/On
• Off: AUTOHOLD switch is off.
• On: AUTOHOLD switch is on.
1U
B2_VOLT
V
Displays voltage at electrical supply unit (ESU) terminal 5C (power supply)
5C
B7_VOLT
V
Displays voltage at electrical supply unit (ESU) terminal 4H (power supply)
4H
BACK_UP_VOLT
V
Displays intermediate voltage of back-up power supply.
5G
BGLR_HORN
Off/On
• Off: Theft-deterrent horn is not operated.
• On: Theft-deterrent horn is operated.
2D
BRK_SW
Off/On
• Off: Brake switch (No.1 signal) is off.
• On: Brake switch (No.1 signal) is on.
5D
CARGO_LAMP_STAT
OFF/ON/Fail(Circuit Short to GND)
• OFF: Trunk compartment light (4SD)/cargo compartment light (5HB) does not illuminate.
• ON: Trunk compartment light (4SD)/cargo compartment light (5HB) illuminates.
• Fail(Circuit Short to GND): Short to ground in trunk compartment light (4SD)/cargo compartment light (5HB) circuit is detected.
5I
CARGO_SW
Close/Open
• Close: Trunk lid (4SD)/liftgate (5HB) is close.
• Open: Trunk lid (4SD)/liftgate (5HB) is open.
3H
CLOSED_FUEL_TANK
OFF/ON
• OFF: Sealed tank is not equipped.
• ON: Sealed tank is equipped.
3C, 3A, 1W, 1X
COUPLING_TEMP_SEN
Note
• Displays in the M-MDS but it does not operate.
DOOR_SW_L/F
Close/Open
• Close: Front door (LH) is closed.
• Open: Front door (LH) is open.
5J
DOOR_SW_L/R
Close/Open
• Close: Rear door (LH) is closed.
• Open: Rear door (LH) is open.
5L
E_LATCH_MOTOR
Not Drive/Drive
• Not Drive: Trunk lid latch and release actuator (4SD)/liftgate latch and lock actuator (5HB) is not operated.
• Drive: Trunk lid latch and release actuator (4SD)/liftgate latch and lock actuator (5HB) is operated.
4G
FUEL_LID_MOTOR_L
OFF/ON
• OFF: Fuel-filler lid lock actuator is not operated to lock.
• ON: Fuel-filler lid lock actuator is operated to lock.
FUEL_LID_MOTOR_STAT
Not Drive/Lock/UnLock
• Not Drive: Fuel-filler lid lock actuator motor is not operated.
• Lock: Fuel-filler lid lock actuator motor perform a lock operation.
• UnLock: Fuel-filler lid lock actuator motor perform a unlock operation.
FUEL_LID_MOTOR_UL
OFF/ON
• OFF: Fuel-filler lid lock actuator is not operated to unlock.
• ON: Fuel-filler lid lock actuator is operated to unlock.
FUEL_LID_SW
Note
• Displays in the M-MDS but it does not operate.
FUEL_LID_ULCK_REQ
OFF/ON
• OFF: All door unlock signal is not received.
• ON: All door unlock signal is received.
3C, 3A, 1W, 1X
FUEL_LID_LCK_REQ
Not Drive/Lock/UnLock
• Not Drive: All door lock signal and all door unlock signal are not received.
• Lock: All door lock signal is received.
• UnLock: All door unlock signal is not received.
3C, 3A, 1W, 1X
FUEL_SEN_MAIN_GAUGE
Displays the fuel gauge
1J, 1F
FUEL_SEN_SUB_GAUGE
Note
• Displays in the M-MDS but it does not operate.
FUEL_SEN_VOLT
Fuel gauge sender unit voltage
5P, 5C
IG1_VOLT
V
Displays voltage at electrical supply unit (ESU) terminal 5K (ignition power supply)
5K
LID_STOP_LAMP
Note
• Displays in the M-MDS but it does not operate.
OIL_TEMP_SEN
Note
• Displays in the M-MDS but it does not operate.
PARK_BRK_SW
Note
• Displays in the M-MDS but it does not operate.
R_FOG_REQ
Note
• Displays in the M-MDS but it does not operate.
R_FOG_STAT
Note
• Displays in the M-MDS but it does not operate.
R_TURN_STAT_L
Off/On
• Off: Rear turn light (LH) is turned off.
• On: Rear turn light (LH) is turned on.
4D
R_TURN_STAT_R
Off/On
• Off: Rear turn light (RH) is turned off.
• On: Rear turn light (RH) is turned on.
4B
R_WIP_AUTO_STOP_SW
Parking Pos/Not Parking Pos
• Parking Pos: Auto stop switch is on.
• Not Parking Pos: Auto stop switch is off.
3D
R_WIP_STAT
Off/On
• Off: Rear wiper is not operated.
• On: Rear wiper is operated.
4J
REV_LAMP_CTRL_STAT
Off/On
• Off: Back-up light on signal is not sent from relectrical supply unit (ESU).
• On: Back-up light on signal is sent from electrical supply unit (ESU).
3C, 3A, 1W, 1X
REV_LAMP_STAT
Off/On
• Off: Back-up lights are not illuminated.
• On: Back-up lights are illuminated.
5O
S_BELT_STAT_C/R
Not insert/Insert
• Not insert: Rear center buckle switch is on.
• Insert: Rear center buckle switch is off.
1O
S_BELT_STAT_L/3RD
Note
• Displays in the M-MDS but it does not operate.
S_BELT_STAT_L/R
Not insert/Insert
• Not insert: Rear buckle switch (LH) is on.
• Insert: Rear buckle switch (LH) is off.
1Q
S_BELT_STAT_R/3RD
Note
• Displays in the M-MDS but it does not operate.
S_BELT_STAT_R/R
Not insert/Insert
• Not insert: Rear buckle switch (RH) is on.
• Insert: Rear buckle switch (RH) is off.
1M
SEAT_SEN_C/3RD
Note
• Displays in the M-MDS but it does not operate.
SEAT_SEN_C/R
Note
• Displays in the M-MDS but it does not operate.
SEAT_SEN_L/3RD
Note
• Displays in the M-MDS but it does not operate.
SEAT_SEN_L/R
Note
• Displays in the M-MDS but it does not operate.
SEAT_SEN_R/3RD
Note
• Displays in the M-MDS but it does not operate.
SEAT_SEN_R/R
Note
• Displays in the M-MDS but it does not operate.
SOL_CUR
Note
• Displays in the M-MDS but it does not operate.
STOP_LAMP_STAT
Off/On
• Off: High-mount brake light is turned off.
• On: High-mount brake light is turned on.
5B, 3B
T/LGT_REQ
OFF/ON
• OFF: Trunk lid release signal (4SD)/liftgate release signal (5HB) is not received.
• ON: Trunk lid release signal (4SD)/liftgate release signal (5HB) is received.
3C, 3A, 1W, 1X
TAIL_LAMP_STAT
Off/On
• Off: Taillights are not illuminated.
• On: Taillights are illuminated.
5R
TNS_LAMP_STAT
Off/On
• Off: TNS (parking lights) is turned off.
• On: TNS (parking lights) is turned on.
5E
TOWBAR_SW
Off/On
Note
• It is displayed, however, if an accessory part is installed, it cannot be used.
TOWING_SW
Off/On
Note
• It is displayed, however, if an accessory part is installed, it cannot be used.
VPWR
V
Displays voltage at electrical supply unit (ESU) terminal 5P (power supply)
5P