PROGRAMMED POSITION CANNOT BE DELETED [POSITION MEMORY SYSTEM]
PROGRAMMED POSITION CANNOT BE DELETED [POSITION MEMORY SYSTEM]
SM2336309
id0903p5067500
Outline
Description
|
• When deleting programming, the deletion completed sound is not activated.
• When programming a position, the programming error sound is activated.
|
Possible cause
|
• Position memory switch malfunction
• Instrument cluster malfunction
• Notification and warning speaker malfunction
• Position memory control module malfunction
|
Diagnostic Procedure
Step |
Inspection |
Results |
Action |
---|---|---|---|
1
|
VERIFY ALL SYSTEM DTCs
• Perform the DTC inspection. (See DTC INSPECTION.)
• Are any DTCs displayed?
|
Yes
|
Repair the malfunctioning location according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
INSPECT POSITION MEMORY SWITCH FOR MALFUNCTION
• Inspect the applicable part. (See POSITION MEMORY SWITCH INSPECTION.)
• Is the part normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
3
|
INSPECT INSTRUMENT CLUSTER FOR MALFUNCTION
• Inspect the applicable part. (See INSTRUMENT CLUSTER INSPECTION [(US)].)
• Is the part normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
4
|
INSPECT NOTIFICATION AND WARNING SPEAKER FOR MALFUNCTION
• Inspect the applicable part. (See NOTIFICATION AND WARNING SPEAKER INSPECTION.)
• Is the part normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunctioning location and perform the repair completion verification.
|
||
Repair completion verification
|
VERIFY THAT VEHICLE IS REPAIRED
• Install/connect the part removed/disconnected during the troubleshooting procedure.
• Has the malfunction symptom been eliminated?
|
Yes
|
Complete the symptom troubleshooting. (Explain contents of repair to customer)
|
No
|
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
• If the malfunction is not resolved, replace the position memory control module. (See POSITION MEMORY CONTROL MODULE REMOVAL/INSTALLATION [(US)].)
|