ABNORMAL SHIFTING [EV6A-EL, EV6AX-EL]
ABNORMAL SHIFTING [EV6A-EL, EV6AX-EL]
SM2566157
id0503n9101200
Troubleshooting item |
Abnormal shifting |
---|---|
Description
|
• Shifts incorrectly (incorrect shift pattern).
|
Possible cause
|
1. Signal malfunction
2. Low-G (XY) sensor (built into SAS control module) malfunction
|
System wiring diagram
|
• Not applicable
|
Connector diagram
|
• Not applicable
|
Diagnostic procedure
Step |
Inspection |
Results |
Action |
---|---|---|---|
1
|
INSPECT SIGNAL PARTS FOR MALFUNCTION
• Inspect the value at the following PCM PIDs using the M-MDS. (See PID/DATA MONITOR INSPECTION.)
• Is there any malfunction? (See PID/DATA MONITOR TABLE [PCM (SKYACTIV-G (US))].)
|
Yes
|
Repair or replace any malfunctioning parts according to the inspection result.
|
No
|
Go to the next step.
|
||
2
|
INSPECT SIGNAL PARTS FOR MALFUNCTION
• Inspect the value at the following ESU PIDs using the M-MDS. (See PID/DATA MONITOR INSPECTION.)
• Is there any malfunction? (See PID/DATA MONITOR TABLE [ELECTRICAL SUPPLY UNIT (ESU) (US)].)
|
Yes
|
Repair or replace any malfunctioning parts according to the inspection result.
|
No
|
Go to the next step.
|
||
3
|
VERIFY IF MALFUNCTION CAUSE IS LOW-G (XY) SENSOR
• Is there any malfunction?
|
Yes
|
Replace the SAS control module.
|
No
|
Symptom troubleshooting is completed.
|